Send Message
CITEST DIAGNOSTICS INC. info@citestdiagnostics.com
Keta/mine KET Rapid Test CutOff Concentration Of 500ng/Ml Accuracy 98.0%

Keta/mine KET Rapid Test CutOff Concentration Of 500ng/Ml Accuracy 98.0%

  • High Light

    KET Drug Abuse Test Kit

    ,

    Ketamine Drug Abuse Test Kit

    ,

    Ketamine Rapid Test

  • Product Name
    Keta/mine (KET)Rapid Test , Cut-off Concentration Of 500ng/ml ,Accuracy 98.0%
  • Cat No.
    DKE-102
  • Principle
    Chromatographic Immunoassay
  • Format
    Dipstick, Cassette, Panel, Device, Cup
  • Specimen
    Urine,Oral Fluid,Powder,WB/S/P,Hair
  • Reading Time
    5 Minutes
  • Pack
    10T/25T/40T/50T
  • Sensitivity
    97.5%
  • Specificity
    98.2%
  • Accuracy
    98.0%
  • Cut-Off
    500ng/ml
  • Place of Origin
    -
  • Brand Name
    Citest
  • Certification
    CE
  • Model Number
    DKE-102
  • Minimum Order Quantity
    N/A
  • Price
    negotiation
  • Packaging Details
    40T/50T
  • Delivery Time
    2-4 Weeks
  • Payment Terms
    L/C, T/T
  • Supply Ability
    10 M tests/month

Keta/mine KET Rapid Test CutOff Concentration Of 500ng/Ml Accuracy 98.0%

Keta/mine (KET)Rapid Test , cut-off concentration of 500ng/ml ,Accuracy 98.0%
 
A rapid test for the qualitative detection of Keta/mine in human urine.
For medical and other professional in vitro diagnostic use only.
 
Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Device, Cup
Specimen Urine,Oral Fluid,Powder,WB/S/P,Hair
Certificate CE
Reading Time 5 minutes
Pack 10T/25T/40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 97.50%
Specificity 98.20%
Accuracy 98.00%
Cut-Off 50 ng/mL* ,100 ng/mL, 200 ng/mL, 300 ng/mL, 500 ng/mL, 1000 ng/mL*,0.2 ng/mg

 

 

INTENDED USE
 
The KET Rapid Test Cassette (Urine) is a rapid chromatographic immunoassay for the detection of Keta/mine in human urine at a cut-off concentration of 500ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.
 
This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.
 
SUMMARY
 
Keta/mine is a dissociative anesthetic developed in 1963 to replace PCP (Phen/cyclidine). While Keta/mine is still used in human anesthesia and veterinary medicine, it is becoming increasingly abused as a street drug. Keta/mine is molecularly similar to PCP and thus creates similar effects including numbness, loss of coordination, sense of invulnerability, muscle rigidity, aggressive / violent behavior, slurred or blocked speech, exaggerated sense of strength, and a blank stare.
 
There is depression of respiratory function but not of the central nervous system, and cardiovascular function is maintained. The effects of Keta/mine generally last 4-6 hours following use. Keta/mine is excreted in the urine as unchanged drug (2.3%) and metabolites (96.8%).
 
The KET Rapid Test Cassette (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Keta/mine in urine. The KET Rapid Test Cassette (Urine) yields a positive result when Keta/mine in urine exceeds 500ng/ml.
 
PRINCIPLE
 
The KET Rapid Test Cassette (Urine) is a rapid chromatographic immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.
 
During testing, a urine specimen migrates upward by capillary action. Keta/mine, if present in the urine specimen below 500ng/ml, will not saturate the binding sites of the antibody coated particles in the test. The antibody coated particles will then be captured by immobilized Keta/mine conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Keta/mine level exceeds 500ng/ml because it will saturate all the binding sites of anti-Keta/mine antibodies.
 
A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.
 
REAGENTS
 
The test contains mouse monoclonal anti-Keta/mine antibody-coupled particles and Keta/mine-protein conjugate. A goat antibody is employed in the control line system.
 
PRECAUTIONS
  • For medical and other professional in vitro diagnostic use only. Do not use after the expiration date.
  • The test should remain in the sealed pouch until use.
  • All specimens should be considered potentially hazardous and handled in the same manner as an infectious agent.
  • The used test should be discarded according to local regulations.
DIRECTIONS FOR USE
 
Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
 
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120 uL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
 
3. Wait for the color line(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.
Keta/mine KET Rapid Test CutOff Concentration Of 500ng/Ml Accuracy 98.0% 0
 
INTERPRETATION OF RESULTS
 
(Please refer to the illustration above)
NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the Keta/mine concentration is below the detectable level (500ng/ml).
 
*NOTE: The intensity of the color in the test line region (T) may vary depending on the concentration of keta/mine present in the specimen. Therefore, any shade of color in the test line region (T) should be considered negative.
 
POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the Keta/mine concentration exceeds the detectable level (500ng/ml).
 
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test. If the problem persists, discontinue using the lot immediately and contact your local distributor.
 
QUALITY CONTROL
 
A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique. Control standards are not supplied with this kit; however, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.
 
Order Information
 
Cat. No. Product Specimen Pack
DKE-102 Keta/mine (KET)Rapid Test Cassette Urine 40T
DKE-114 Keta/mine (KET)Rapid Test Panel Urine 40 T
DKE-101 Ket/amine (KET)Rapid Test Dipstick Urine 50 T
DKE-802 Keta/mine(KET) Rapid Test Cassette Oral Fluid 25 T
DKE-803 Keta/mine(KET) Rapid Test Device Oral Fluid 25 T
DKE-402 Keta/mine(KET) Rapid Test Cassette WB/S/P 40 T
DKE-X14 Keta/mine (KET)Rapid Test Panel Powder 25 T
DKE-H902 Keta/mine (KET)Rapid Test Cassette Hair 10 T